2x6+6awg Paludina Aluminum Conductor Triplex Overhead Service Drop Cable Wire

Triplex Service Drop Cable 6AWG Paludina #6

Code Word: Paludina

Size AWG (Phase Conductors): 6

Voltage: 600V

Number of cores: Triplex

Package : Export wooden drum & iron wooden drum or as customer require

Email:uvlead@aliyun.com

Email:tlfast@aliyun.com

6-6-6 Paludina Aluminum Conductor Triplex Overhead Service Drop Cable Wire Application


6-6-6 Paludina Triplex aluminum wire has three conductors, with one of them being for neutral path, and two electrodes. Primarily used for 120 volt overhead service applications such as street lighting, outdoor lighting, and temporary service for construction. To be used at voltages of 600 volts phase-to-phase or less and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for crosslinked polyethylene (XLP) insulated conductors. A bare messenger wire of this electrical cable is bonded closely on the two insulated aluminum conductors, which are individually insulated with black cross-linked polyethylene for protection.

6-6-6 Paludina Aluminum Conductor Triplex Overhead Service Drop Cable Wire Standard

• B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
• B-231 Aluminum Conductors, Concentric-Lay-Stranded.
• B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
• B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors.
• ICEA S-76-474-Neutral-supported Power Cable Assemblies With Weather-Resistant Extruded Insulation Rated 600Volts

 


CONSTRUCTION :

6-6-6 Paludina Aluminum Conductor Triplex Overhead Service Drop Cable Wire Construction

Phase Conductor

Strand or Compressed 1350-H19 Series Aluminum Conductor.

Neutral(Messenger )Conductor

Bare ACSR messenger. 

Insulation

Black Cross Linked Polyethylene (XLP) Insulation.



TECHNICAL DATA :

6-6-6 Paludina Aluminum Conductor Triplex Overhead Service Drop Cable Wire Technical Data

Rated voltage

V

600

Test voltage

Veff kV/Hz

4/50

Laying temperature

°C

min. -5

Operating temperature

°C

-30 ~ +90

Conductor temperature

°C

max. +90

Short-circuit temperature

°C/s

max. +250 /5

Bending radius (min.)

mm

20 × Ø of cable


PARAMETER :

6-6-6 Paludina Aluminum Conductor Triplex Overhead Service Drop Cable Wire Parameter

Code NamePaludina
Phase Conductor MaterialAAC
Phase Conductor Size (awg)6
Phase Conductor Stranding7
Phase Conductor insulation MaterialXLPE
Phase Conductor Insulation Thickness (mils)45
Bare Neutral Messenger MaterialACSR
Bare Neutral Messenger Size(awg)6
Bare Neutral Messenger Stranding6/1
Bare Neutral Messenger Breaking Strength (Lbs)1190 
Weight Per (Lbs/1000 ft) 110
Ampacity (Amps)85 


:
PHASE CONDUCTORSACSR COMPACT BARE NEUTRALOVERALL
SIZE
(AWG OR kcmil)
NO. OF
WIRES
COND.
O.D. (mm)
MIN. INS.
THKN. (mm)
NOM. INS.
O.D.
(mm)
SIZE
(AWG OR kcmil)
NO. OF WIRES
(A1/S1A)
RATED
STRENGTH
COND.
O.D.
(mm)
EFFECTIVE
O.D.
(mm)
APPROX.AMPACITY
kNWEIGHT

(kg/km)
475.411.047.7566/15.185.0315220125
276.881.049.1446/18.146.3518333165
1/078.531.3711.626/112.48.1123527220
2/079.651.3712.616/115.58.9925650255
3/0710.71.3713.81/06/118.910.128803290
4/0712.11.3715.22/06/123.511.530996335
266.81913.61.8317.73/06/129.612.8351282390
336.41915.31.8319.44/06/137.314.3391588450
397.51916.71.8320.8266.826/750.116.3421890500
4771918.31.8322.4336.426/762.318.3462277560


Related products